Hot-Oil Expansion & Deaerator Tank

Vented expansion, deaeration and reserve tank for the closed thermic-oil loop — sized for total system expansion with enough reserve to protect the pumps.

Enquire About This Product

Overview

A thermic-oil loop is closed and unpressurized: the oil expands roughly 7% by volume from cold start to 300 °C operating temperature, and that expansion has to go somewhere. The expansion tank is the somewhere — mounted high enough to keep the circulating pumps in flooded suction under all temperatures, vented to atmosphere so light volatiles and entrained moisture leave the loop, and sized to hold the full expansion volume plus a working reserve. Under-sizing is the classic thermic-plant failure: cold-start overflow, or worse, pump cavitation and heater coil starvation on hot afternoons. We size the tank from your exact circuit inventory, not a rule of thumb, and supply it with the level glass, vent, drain and nitrogen-connection provisions.

Technical Data

Design codeASME VIII Div. 1 / API 650
Design pressureAtmospheric / FV
Design temperature350 °C (with thermal-sleeve fill nozzle)
Material of constructionSA-516 Gr. 70
Corrosion allowance3 mm
Fill nozzleThermal-sleeved cold-fill connection
InstrumentationLevel glass, low-level alarm, thermometer well
TestingLeak test, stand load verification

Applications

  • Thermic fluid heater loops
  • Hot-oil circulation systems
  • Any closed-loop mineral-oil heating circuit

Materials & Standards

  • ASME VIII Div. 1 / API 650
  • Hot-oil system practice per heater OEM conventions

Options & Variants

  • Nitrogen-blanket connection (paired with our N₂ system)
  • Insulation & cladding
  • Duplex level gauges
  • Oil-dumping/transfer pump provision