Heating & Thermal
Thermic heaters, process heaters & insulation
Every re-refining train is a heat business: feed must be dehydrated, vaporized under vacuum and kept hot through the circuit. Thermic fluid heaters are the industry choice for this duty — a closed hot-oil loop delivers uniform, controllable heat above 250 °C without the cost and pressure class of steam boilers. We supply the heater, burner assembly, fuel system, flue stack and the insulation package that keeps the heat where it belongs.
- Closed-loop hot oil — no boiler-water treatment or corrosion
- Capacity sized with expansion margin at quotation stage
- Burner options matched to locally available KSA fuels
- Full insulation and cladding package for the hot circuit

Best SellerThermic Fluid Heaters
Oil- and gas-fired thermic fluid heaters with complete assembly structure and accessories — the heart of the heating circuit.
- Capacity range: 10–20 lakh kcal/hr (standard); other duties on request
- Outlet temperature: Up to 300 °C class
- Fuel: Diesel / gas / dual-fuel burner options

Process Heaters with Burner Assembly
Direct-fired process heaters with matched burner assemblies for pre-heating feed and distillation duty.
- Duty: Sized to feed pre-heat requirement
- Burner: Matched assembly, flame safeguard included
- Fuel: Diesel / gas, to site availability

Fuel Tank for Thermic Boiler
Square fuel storage tank for the thermic heater fuel system, with level indication and safety fittings.
- Capacity: 1,000 L
- Form: Square, space-saving layout
- Fittings: Fill, vent, level gauge, drain

Thermal Insulation Package
Complete plant thermal insulation — aluminium cladding over high-temperature packing for boilers, heaters, columns and piping.
- Coverage: Full hot circuit — equipment, piping, valves
- Packing: High-temperature mineral/rock wool class
- Cladding: Aluminium roll, weather-sealed

Flue Stack & Ducting
Flue stacks, ducts and foundation plates for thermic heaters and boilers, engineered to site layout.
- Foundation plates: 15 mm thickness, drawings issued
- Scope: Stack, ducting, supports and access
- Height: Per dispersion and site layout
EfficiencyWaste-Heat Recovery Economizer
Finned-coil flue-gas heat-recovery unit that recaptures stack losses from the thermic heater — cutting fuel consumption 5–8% and paying for itself in months.
- Function: Flue-gas heat recovery to thermic-oil return / feed preheat
- Typical fuel saving: 5–8% of heater fuel
- Flue-gas inlet: 200–350 °C (per heater duty)

Hot-Oil Expansion & Deaerator Tank
Vented expansion, deaeration and reserve tank for the closed thermic-oil loop — sized for total system expansion with enough reserve to protect the pumps.
- Function: Expansion volume + deaeration + circulation reserve
- Sizing basis: Total loop oil inventory × expansion coefficient + 20% reserve
- Elevation: Mounted ≥ 3 m above pump centreline (flooded suction)