Dehydration & Degassing Vessel

Flash dehydration vessel with demister and vent condenser — removes water, gasoline-range lights and dissolved VOCs before oil ever reaches the vacuum train.

Enquire About This Product

Overview

Every re-refinery starts with the same step: the raw used oil arrives carrying 3–10% water, gasoline-range dilution, solvents and dissolved gases. Feed that straight into a heated distillation train and you get foaming, unstable vacuum and fouled heaters. The dehydration vessel flashes the preheated feed — water and lights vaporize, pass through a wire-mesh demister that stops carryover, then condense in the vent condenser where oil and water settle and separate by gravity. The dry, de-lighted oil drains to the transfer pump and the vacuum train sees a stable, predictable feed. We supply the vessel with internals, level instrumentation nozzles and the vent condenser as a matched pair.

Technical Data

Design codeASME VIII Div. 1 / API 650 conventions (atmospheric option)
Design pressureFV / 3.5 barg
Design temperature200 °C (feed preheat to 120–160 °C operating)
Material of constructionSA-516 Gr. 70 + SS304 lining options for corrosive feeds
Corrosion allowance3 mm
DemisterSS304 knitted mesh, 100–150 mm thick, 99%+ droplet capture at rated velocity
TestingHydrostatic test, nozzle load check
Instrumentation nozzlesLevel (LG/LT), temperature (TI), pressure (PI), high-level alarm

Applications

  • Raw used-oil reception & pre-treatment
  • Flash-point adjustment of feed
  • Protection of downstream heaters and vacuum systems

Materials & Standards

  • ASME VIII Div. 1
  • API 12F/650 tank conventions where atmospheric
  • Demister sizing per standard entrainment-velocity practice

Options & Variants

  • Vacuum-assist connection for low-flash feeds
  • Agitator for sludge-heavy feeds
  • Insulation & cladding
  • Skid-mounted with condenser, receiver and transfer pump