Agitated Thin-Film Evaporator (ATFE)

Core Process

Wiped-film evaporator for high-vacuum distillation of dehydrated used oil — the industry-standard unit that separates base-oil distillate from asphaltic residue without thermal cracking.

Enquire About This Product

Overview

Used oil cannot be distilled at atmospheric pressure: the temperatures needed would crack the oil and destroy the very properties being recovered. The agitated thin-film evaporator solves this with a heated cylindrical shell and an internal rotor whose blades spread the oil as a turbulent film a fraction of a millimetre thick on the heated wall. Residence time drops to seconds, heat transfer stays intense, and metals, polymers, carbon and asphaltenes leave with the bottom residue while clean distillate flashes off under deep vacuum. This is the workhorse of every modern re-refinery built in the last three decades — specified by STP, VTA and every serious licensor of used-oil technology. We fabricate the shell, jacket, rotor and drive train, hydro-test the jacket, and run a vacuum leak test before dispatch.

Technical Data

Design codeASME VIII Div. 1 (vacuum + jacket pressure design)
Jacket design pressure10 barg typical (thermic-oil duty)
Design temperature350 °C shell / 400 °C jacket
Material of constructionSA-240 Gr. 304/316L wetted parts; CS jacket
Corrosion allowance1.5 mm CS / 0 mm SS
Rotor speed100–400 rpm, VFD controlled
TestingHydrostatic jacket test, vacuum leak test ≤ 1 mbar·L/s
Surface finishRa ≤ 0.8 µm wetted surface, pickle & passivate

Applications

  • Base-oil recovery from used lubricating oil
  • High-boiling residue concentration
  • Deodorizing / light-end stripping under vacuum

Materials & Standards

  • ASME VIII Div. 1
  • TEMA nomenclature for jacketed vessels
  • ASTM D2892 boiling-range conventions for cut definition

Options & Variants

  • CIP spray system for the vapor body
  • Double mechanical seal with barrier fluid
  • Insulation & aluminium cladding package
  • Skid-mounted with condenser, receiver and vacuum connection